Eaton Wiring Devices Arrow Hart TRSGF15W Duplex Tamper-Resistant GFCI Receptacle, 125 VAC, 15 A, 2 Poles, 3 Wires, White

EATON TRGF15W 15 AMP WHITE SELF TEST GFCI RECEPTACLE TAMPER RESISTANT

GFCI Receptacles }

Eaton Wiring Devices Arrow Hart TRSGF15W Duplex Tamper-Resistant GFCI Receptacle, 125 VAC, 15 A, 2 Poles, 3 Wires, White

3471115 Product ID:3471115
Famous Supply
  • Dimensions: 4.2 in L x 1.68 in W x 1.27 in D
  • Enclosure: IP65
  • Frequency Rating: 60
  • Material: Thermoplastic
  • NEMA Rating: NEMA 5-15R
  • Series: TRSGF
  • Temperature Rating: -35 to 66 deg c
  • Terminal Type: Back/Side Wired
  • Type: Duplex Tamper-Resistant
  • Voltage Rating: 125
  • Amperage Rating: 15
  • Number of Poles: 2
  • Number of Wires: 3
  • Color: White
GFCI receptacles are designed with the safety of the user in mind. In commercial and industrial areas like public bathrooms, break rooms and food service areas, the NEC requires GFCI receptacles. Arrow Hart Self-Test GFCI receptacles are UL Listed and fully compliant with all of the latest UL943 Class A GFCI and UL498 requirements. The Self-Test GFCIs conduct an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage.
  • Features
  • Standards & Approvals
  • Includes
  • Application
If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced
Performs periodic self-tests to ensure integrity of GFCI protection
Visual trip indicator light gives quick notification of a tripped or end of life condition
Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards
Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
Tamper resistant shutters help prevent foreign objects from being inserted
Line side terminals are backed out and staked for fast installation
Horizontal test/reset button alignment provides larger unobstructed area
Test and reset buttons are color matched to provide superior aesthetics
Tapered back wire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
When downstream receptacles are wired from load side, a 20A feed through rating offers full protection
Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly
Tri-combo head terminal and mounting screws
Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations
Thermoplastic, polypropylene; nylon 6/6 top housing, thermoplastic, PVC bottom housing, 0.047 in thick steel, zinc plated strap, 0.03 in thick brass line contacts materials
Brass/nickel plated steel terminal and ground screws, brass plated steel terminal clamps
Withstands 2000 V per UL498 dielectric voltage
V2 rated UL94 flammability
Current interrupting at full-rated current, 0.025 sec class A trip time, Short circuit testing meets and exceeds 10 kA, maximum interrupting capacity of 20 A
#14 to 10 AWG terminal accommodation, Back Wire and Side Wire
cULus Listed to UL 498
UL 943
E60120
2011 NEC Article 406.11 Compliant
CSA Certified
NOM Certified
Matching Thermoplastic Wallplate
Commercial, Industrial and Institutional