if (this.Model.StructuredPageData.IsNotBlank() && (this.Model.StructuredPageData.IndexOf(availabilityKey) != -1 || this.Model.StructuredPageData.IndexOf(priceKey) != -1)) { this.Model.StructuredPageData = string.Empty; //} }

GeniSys Primary Oil Burner Control, 120v, 15 SEC Lockout/Valve On

BECKETT 7505P1515U GENISYS PRIMARY ADVANCE OIL BURNER SAFETY CONTROL

Hydronic Boiler Parts & Accessories }

GeniSys Primary Oil Burner Control, 120v, 15 SEC Lockout/Valve On

3631295 MFG #: 7505P1515U Product ID:3631295
Famous Supply
  • Series: GeniSys
  • Suitable For Use With: Oil Burners
The Beckett GeniSys® 7505 Oil Burner Control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys® 7505 is used with the GeniSys® CAD Cell Flame Detector Kit 7006U to control the oil burner’s motor, igniter, and optional solenoid valve. It has front-mounted, 24 VAC thermostat terminals compatible with both mechanical and many power stealing thermostats. The control operates the burner with interrupted ignition with a 15 second lockout time.
  • Features
Water Resistant
Thermostat and boiler control compatible
Customizable pre-time and post-time
Three status lights for system monitoring and diagnostics
Welded relay protection with redundant motor relays
Limited reset and limited recycle
Sleek, modern design
Technician Pump Prime mode
Two communication ports for adding alarm contacts, programming display, and/or future