if (this.Model.StructuredPageData.IsNotBlank() && (this.Model.StructuredPageData.IndexOf(availabilityKey) != -1 || this.Model.StructuredPageData.IndexOf(priceKey) != -1))
{
this.Model.StructuredPageData = string.Empty;
//}
}
3/4 in Hose Connection Vacuum Breaker
WATTS 0061877 8A VACUUM BREAKER 3/4" HOSE CONNECTION
Backflow Preventers
Brand:
}
3/4 in Hose Connection Vacuum Breaker
542184
MFG #: 0061877
Product ID:542184
Famous Supply
-
Dimensions:
1-1/2 in L x 1-1/2 in H in
-
Pressure Rating:
125 psi
-
Series:
8 Series
-
Temperature Rating:
180 deg f
-
Nominal Size:
3/4 in
-
End Style:
Female Hose Threaded x Male Hose Threaded
-
Body Material:
Brass
-
Domestic/Import:
Import
Series 8A Hose Connection Vacuum Breakers permit the attachment of portable hoses to hose thread faucets and prevent the reverse flow of polluted water from entering into the potable water supply due to backsiphonage. It consists of a brass body construction (8A) or chrome finish (8AC), stainless steel working parts, a rubber diaphragm and disc, and a draining stem. Series 8A's non-removal feature prevents the removal of the valve once installed. It is ideal for inside and outside, health hazard installations requiring non-continuous pressure such as service sinks, swimming pools, photo developing tanks, laundry tubs, wash racks, dairy barns, marinas, and general outside gardening uses. Check with local inspection authorities for installation requirements. Maximum Pressure:125 psi (8.6 bar).
-
Features
-
Warranty
-
Standards & Approvals
-
Application
Brass body |
3/4 in standard female hose thread |
Ideal for inside and outside, health hazard installations requiring non-continuous pressure such as service sinks, swimming pools, photo developing tanks, laundry tubs, wash racks, dairy barns, marinas and general outside gardening uses |
Maximum pressure is 125 psi |
Manual drain |
No special tools required for servicing |
Stainless steel working parts for longevity |
Durable rubber diaphragm and disc for consistent positive seating |
Standardly equipped to allow sill cock to be drained |
Do not use where discharge of water is objectionable |
Series 8 is tested and certified under ANSI A112.1.3 (ASSE 1011), which precludes use under continuous pressure, this valve should only be used in areas where spillage of water will not cause damage |
Device should only be installed on approved sill cocks containing at least four full threads |
Non-removable once installed |
ANSI A112.1.3 |
ASSE 1011 |
cCSAus B64.2 |
IAPMO/UPC Listed |
PROP65: This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm. |
Hose Thread Faucets and Health Hazard |