LFN45BM1-U-070 1/2 Standard Capacity Pressure Reducing Valve, Set @ 70 PSI, 1/2 in Nominal, NPT Union x FNPT End Style, 400 psi Pressure, Copper Silicon Alloy Body, Domestic

WATTS 0009502 LEAD-FREE 1/2" LFN45BM1-U-070 WATER PRESSURE REDUCING VALVE (WESTERN PA)G

Pressure Reducing Valves
Brand: Watts logo
}

LFN45BM1-U-070 1/2 Standard Capacity Pressure Reducing Valve, Set @ 70 PSI, 1/2 in Nominal, NPT Union x FNPT End Style, 400 psi Pressure, Copper Silicon Alloy Body, Domestic

3311696 MFG #: 9502 Product ID:3311696
Famous Supply
  • Inlet to Outlet Length: 4-1/16 in
  • Media: Water
  • Pressure Class: 400 psig
  • Series: LFN45B
  • Softgoods Material: Thermoplastic Seat/Reinforced EPDM Diaphragm
  • Temperature Rating: 33 to 180 deg f
  • Trim Material: Stainless Steel
  • Type: Pressure Reducing
  • Nominal Size: 1/2 in
  • End Style: NPT Union Inlet x FNPT Outlet
  • Pressure Range: 400 psi
  • Flow Rate: Variable dependent on pressure drop gpm
  • Body Material: Lead Free Cast Copper Silicon Alloy
This 1/2 in lead free water pressure reducing valve is designed to reduce incoming water pressure to protect plumbing systems and reduce water consumption for commercial, industrial and residential applications. This assembly consists of a lead free bronze body, NPT threaded union inlet and FNPT outlet connection, stainless steel integral strainer, thermoplastic seat module, thermal expansion bypass and a sealed spring cage for waterworks pit installations. The temperature range is 33 to 180 deg F . The pressure rating is set at 70 psi (4.8).
  • Features
  • Warranty
  • Standards & Approvals
  • Application
Integral stainless steel strainer removable for cleaning
Sealed spring cage for accessible outdoor or pit installations
Thermoplastic seat and bronze cage
Bypass feature controls thermal expansion pressure
Pressure setting at 70 psi
EPDM diaphragm
The bypass feature will not prevent the pressure relief valve from opening on the hot water supply system with pressure above 150 psi
A water saving test program concluded that reducing the supply pressure from 80 to 50 psi (551 to 345 kPa) resulted in a water savings of 30%
The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight
25 to 75 psi adjustable reduced pressure
Limited
ASSE 1003
ANSI A112.26.2
CSA B356
IAPMO Listed
NSF/ANSI 61-G
PROP65: This product can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Commercial and Residential